J2E-II

635~1270SCFM
REFRIGERATION COMPRESSED AIR DRYER-J2EII

Features

  1. Automatic logic controller with warning indicator.
  2. Upward axial fan motor better ventilation.
  3. 2in1 Condenser and pre-cooler design. Equipped with filter screen prevent oil vapor on fins.
  4. Pre-set type pressure switch (HPS & LPS), resettable high/low pressure trip switch.
  5. 2in1 patent heat exchanger assembly.
  6. External float drain with manual drain.
  7. Hermetic, scroll type refrigeration compressor.
  8. Eco-friendly HFCs. Reduce energy consumption also mitigating global warming damage.

SN / SG TYPE AIR COOLED

Model J2E-125S
J2E-150S J2E-175S J2E-200S J2E-250S
Capacity (Nm3/min) 18 22 27 30 36
Connection (inch) 3"FL 3"FL 3"FL 3"FL 4"FL
Power Supply (50/60 HZ) (380Volt 3Phase(220V、440V Optional)
Ref. Comp. (KW)
@ET10°C CT54°C
3.6 4.2 4.7 6.5 7.0
Operating Current(A)
@ET5°C CT45°C
6.0 6.4 7.6 9.8 10.2
Full-Load Current (A)
@ET10°C CT54°C
6.7 7.3 8.6 11.0 12.2
Refrigerant
R-407c
Fan motor (W) 600 600 600 600 250×2
Dimension
(mm)
H 1400 1615
L 1280 1800
W 780 950
Net weight (kg) 270/300 280/310 290/320 300/330 400/440
Operating Scope
Inlet temp.:N Type 5~50°C(@40°C)
G Type 5~80°C(@60°C)
Ambient temp.:2~42°C(@38°C)
Dew point:2~10°C(@10°C)
Working pressure:<1.0MPa(@0.7MPa)

Design Condition @60HZ

Ref. Comp.(kw):@ET10°C、CT54°C
Operating current(A):@ET5°C、CT45°C
Full-load current(A):@ET10°C、CT54°C
Customize products available upon request.

SNW / SGW TYPE WATER COOLED

Model J2E-125S
J2E-150S J2E-175S J2E-200S J2E-250S
Capacity (Nm3/min) 18 22 27 30 36
Connection (inch) 3"FL 3"FL 3"FL 3"FL 4"FL
Power Supply (50/60 HZ ) 380Volt 3Phase(220V、440V Optional)
Ref. Comp. (KW)
@ET10°C CT54°C
3.6 4.2 4.7 6.5 7.0
Operating Current(A)
@ET5°C CT45°C
6.0 6.4 7.6 9.8 10.2
Full-Load Current (A)
@ET10°C CT54°C
6.7 7.3 8.6 11.0 12.2
Refrigerant R-407c
Condenser (RT) 3 3 3 5 5
Dimension
(mm)
H 1400 1615
L 1280 1800
W 780 950
Net weight (kg) 280/320 310/350 330/370 350/390 370/410
Cooling water Vol.
(Liter / hr)
N 1800 2200 2700 3000 3600
G 4500 5500 6750 7500 9000
Operating Scope
Inlet temp.:N Type 5~50°C(@40°C)/ G Type 5~80°C(@60°C)
Working pressure:<1.0MPa(@0.7MPa)
Ambient temp.:2~42°C(@38°C)
Dew point:2~10°C(@10°C)
Cooling water pressure:0.2~0.4MPa Cooling water temp.:5~40°C(@32°C)

Design Condition @60HZ


Ref. Comp.(kw):@ET10°C、CT54°C
Operating current(A):@ET5°C、CT45°C
Full-load current(A):@ET10°C、CT54°C
Customize products available upon request.